5
07.10
ABTL48 - ABTR48
3
3A.
Level the base by adjusting the legs underneath.
Check your adjustment with a level.
LEVELING THE BASE.
4
TESTING THE DRAINAGE.
3B.
Tighten the hexagon nut to block the legs height.
3A
3B
4A.
the base with a small amount of water.
4B.
Check for any leakage around the drain (some bub-
bles may appear) and below (if you have access to).
Unplug the drain and assure that the drainage is ef-
There must be no puddle of water accumula-
tion in the base.
4C.
4A
If water doesn’t drain properly even though the base is lev-
eled, do not continue this installation.
Please remove the base and return it to your dealer for
exchange.